G-SPEAK Installation ManualGSM-BASED INTERCOMSYSTEMTM
page 7Technical Specifications10V - 30V DCQuiescent 30mA maximum 300mATwoYesAdjustable at Calling Module using Call Buttons6 wires, min 0.2mm²; Maximu
FIGURE 3. GSM CONTROLLER INTERIORpage 81. GSM Module2. Input/output terminals3. SIM card holder4. Voice communications terminals5. Antenna4. Prod
FIGURE 4. CALLING MODULE INTERIORpage 91. Speaker2. Voice communication terminals3. Call Button 14. Call Button 25. Microphone12453
5. Required Tools and EquipmentScrewdriver – 3.5mm flatSide cutterDrill bits – 5mm masonry; 6mm drill bitSilicone sealantFasteners and rawl plugs
Dimensions of the Calling Module base and mounting holes relative to the Calling Module cover2. Insert screwdriver as shown and unclip the Calling M
page 123. Lift the Calling Module off base. 4. Hold the Calling Module base against the wall at the required height, ensuring that it is vertical.5.
page 1311. Run the cable through the Calling Module base and then hook the Calling Module into the base as shown in Figure 13 and clip back into posit
page 1415. Clip the outer cover back into position. 16. Secure the cover using the fixing screw provided in kit.FIGURE 17.FIGURE 16.It will be necessa
page 152. Remove the cover and unclip and remove the circuit board from the retaining clips. FIGURE 19.FIGURE 18.GSM Controller MountingThe GSM Contr
page 166. Use a 6mm drill bit to open the required cable entry hole.FIGURE 22.CoverCircuitboardPower cableCable saddles6mm drill bitFIGURE 21.Inserti
Company ProfileCompany ProfileCenturion Systems (Pty) Ltd reserves the right to make changes to the products described in this manual without notice a
page 173. Insert the activated SIM card and ensure that the SIM card is correctly oriented. Align the cropped corner to be in the correct position as
page 18FIGURE 27.5. Hook the top of the edge of the cover onto the top of the unit.6. Lower the cover and press securely into position.GSM controlle
page 197. Wiring DiagramsG-SPEAKI04 I03 GND I02 I03 GND 12V-24VP1P2P3P4P5P6Inputs/outputs3 and 4FIGURE 28. GSM CONTROLLERFIGURE 29. CALLING MODULEInpu
I04 I03 GND I02 I03 GND 12V-24Vpage 20FIGURE 30. WIRING DIAGRAMD5-EvoCalling ModuleSolenoidlock104 103 GND 102 103 GND 12V-24VP1P2P3P4P5P6GSM controll
page 218. GSM Network Signal DetectionWhen powered up, the G-SPEAK will beep three times and the signal strength indicator LEDs will light up indicati
9. G-SPEAK Functionalitypage 22Categories of Learned-in PhonesThe G-SPEAK range offers both voice and signalling functionality, each of which provides
page 23There will be a delay of up to ten seconds while the call connects, after which a ringtone will be heard from the Calling Module. Once answered
page 24Switch Phone Functionality The GSM Controller has capacity for ten Switch Phone numbers in the case of the G-SPEAK Classic, or 100 Switch Phone
page 25If you would like confirmation that your SMS command has been successfully received by the G-SPEAK, simply append a space and then the letters
page 26Command ‘AP’As described in the Switch Phone Functionality Section, a Switch Phone is able to activate any of the controller’s outputs via a Mi
Contents IMPORTANT SAFETY INSTRUCTIONS page 2 Quick Setup Steps 1. Glossary of Terms 2. General DescriptionMain Features3. Specifications
Adds phone number 0841234567 to the system, and assigns Output 2 and Output 4 to be activated by a Missed CallConfigures Output 1 to react to Missed C
AirtimeCommand ‘AT’This command allows an airtime voucher to be loaded onto the controller, or remaining airtime to be queried.DescriptionParametersLo
page 29OU1PU – Sets Output 1 as pulsedOU1LA – Sets Output 1 as latchedOU1PT – Sets Output 1 pulse time in millisecondsOU2PU – Sets Output 2 as pulsedO
page 30Settings ParametersDescriptionIN1 – Input 1 configured as inputIN2 – Input 2 configured as inputIN3 – Input 3 configured as inputIN4 –
ATpage 31Sub-parameters:Filter time (milliseconds) 1s = 1000msBlanking time (milliseconds)Input text message (up to 31 characters including spaces)
page 32Configures Channel 1 and Channel 2 as inputs, and sets the Input 1 Filter Time and Blanking Time to 500ms and 30000ms respectively P.xxxx.CO.IN
By SMSing ‘STATUS’ to the G-SPEAK, the G-SPEAK will send an SMS to the phone that sent the STATUS command, indicating firmware version, serial number,
10. Installation HandoverCenturion Systems (Pty) Ltd does not accept any liability caused by improper use of the product, or for use other than that f
These abbreviated instructions are for the experienced installer who needs a checklist to get a standard installation up and running in the minimum of
0.07.A.0190_27012014www.CentSys.comSharecall 0860-CENTURION (0860 236 887)Head Office: +27 11 699 2400Sharecall Technical Support 0861 003 123 or +27
Warnings for the InstallerCAREFULLY READ AND FOLLOW ALL INSTRUCTIONS before beginning to install the product.All installation, repair, and service wo
This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromi
page 41. Glossary of TermsCalled Party: When one of the Call Buttons on the Calling Module is pressed, the Called Party is the person or persons who r
2. General Description page 5The G-SPEAK Classic and G-SPEAK Classic+ are GSM-based intercom systems with advanced functionality. The system comprises
3. SpecificationsFIGURE 1. OVERALL DIMENSIONS FOR GSM CONTROLLERPhysical Dimensionspage 6FIGURE 2. OVERALL DIMENSIONS FOR THE CALLING MODULE116mm120mm