8. Cabling Requirements
FIGURE 27. CABLING REQUIREMENTS
Page 22
Legend
1. 90V /220V - 240V AC mains cable via mains isolator switch (3 core LNE 0,5mm²) ,
or low-voltage 16V AC battery charger supply (2 core 1,5mm²).
2. Intercom cable (n1 + 6 core) to house.
2
3. Master motor (MTR M) or Slave motor (MTR S) cable (minimum, 2 core 2mm +
4 core 0,5mm² multi-stranded) see note .
2
4. Optional radio receiver cable (3 core 0,5mm multi-stranded, optional) .
2
5. Optional Pedestrian Keyswitch (2 core 0,5mm multi-stranded) or optional keypad
2
(3 core 0,5mm multi-stranded).
2
6. Optional infrared Safety Beams (3 core 0,5mm multi-stranded or 4 core 0.5mm² for
CE compliance.)
7. Optional intercom cable (n2+2 core 0,5mm² multi-stranded) to gate station.
8. Optional electric lock (2 core 0.5mm²).
9. Optional Pillar Light cable (3 core, size according to power regulations).
2
10. Optional ground loop for free-exit (1 core 0.5mm multi-stranded - silicone-coated)
Applicable to CP84SM charger only
Mains isolator must be fitted less than 1 metre from controller
Increase cable thickness if Pillar Lights are to be installed
Screened cable is always recommended to provide better protection against lightning - earth one end of screening
Domestic charger only
For optimum range an external receiver can be mounted on the wall
CENTURION has custom VECTOR2 cable available. Order reference: CABLEVEC68. Consult manufacturer of loop
detector for specific details
All cables must be routed in conduit unless underground cable is
being used
Mains isolator must be less than one metre from the operator
Safety Beams are always recommended
To dwelling
Control
Box
Mains
isolator
switch