Centurion VECTOR2 Installation Manual Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
Page 31
FIGURE 48
FIGURE 49
For V500 (500mm operator)
120°
100°
110°
90°
80°
70°
60°
Gate opening angle
Gate swing angle
90° or less
100°
110°
120°
A Value
205
165
144
115
B Value
250
215
180
150
(Only for a 2.5 metre gate or shorter)
Recommended positions
Alternative positions
110mm for A or B would ensure a 10mm clearance between the operator and
gate if the gate is 50mm thick.
Gate
swing
angle
60° - 90° or less
100°
110°
120°
A+B
should
not exceed
460mm
400mm
340mm
285mm
A and B must each be greater
Up to 1.5
metres
110mm
110mm
110mm
Up to 2
metres
110mm
110mm
110mm
Up to 2.5
metres
110mm
110mm
110mm
Up to 3
metres
120mm
120mm
Up to 3.5
metres
140mm
140mm
Up to 4
metres
160mm
160mm
Not
recommended
1600mm extended
1100mm retracted
Page view 34