Page view 37
Page 34
FIGURE 55
FIGURE 56
1600mm extended
1100mm retracted
For V500 (500mm operator) outward
120°
100°
110°
90°
80°
70°
60°
Gate opening angle
Gate swing angle
90° or less
100°
110°
120°
A Value
222
185
155
128
B Value
246
205
170
139
(Only for a 2.5 metre gate or shorter)
Recommended positions
Alternative positions
110mm for A or B would ensure a 10mm clearance between the operator and
gate if the gate is 50mm thick.
Gate
swing
angle
60° - 90° or less
100°
110°
120°
A+B
should
not exceed
455mm
390mm
330mm
275mm
A and B must each be greater
Up to 1.5
metres
110mm
110mm
110mm
Up to 2
metres
110mm
110mm
110mm
Up to 2.5
metres
110mm
110mm
110mm
Up to 3
metres
120mm
120mm
Up to 3.5
metres
140mm
140mm
Up to 4
metres
160mm
160mm
Not
recommended
Page view 37