Page 52
24. Controller Features
This level should only be used if additional safety measures are taken
(e.g. Infrared Safety Beams, etc.).
Collision Force can be set independently per direction of travel.
Menu 2 - Safety (Collision Force)
1. Collision Force
If the gate is obstructed, the internal collision circuitry will activate.
The response of the system to a collision will vary, depending on the Profile
selected (Operating Standard, e.g. ZA). Responses can vary from the gate
stopping, to the gate reversing. The Collision Force can be set from minimum
to maximum in five discrete steps.
A sixth step will disable collision sensing entirely, allowing maximum force to
be achieved. Under this condition, the motor will continue running until it
stalls, at which point a collision will be detected.
Menu 3 - Autoclose
1. Autoclose status
When turned on, the Autoclose feature has the function of automatically
closing the gate after a preset Autoclose time. The Autoclose feature is
automatically turned on when the controller is set for Condominium Mode.
2. Autoclose time
The Autoclose time can be set anywhere from 1 to 255 seconds.
3. Autoclose Override
It is possible for the user to temporarily turn off Autoclose when the Mode of
Operation is Standard or Reversing. To activate Autoclose Override, the
Trg input must be activated and maintained for a period longer than the time
set for the Autoclose Override Time.
The gate response will be to start opening on the Trg trigger, and then to stop
as soon as the Autoclose Override feature is activated. On clearing of the
Trg input, the gate will continue opening until fully open. The Autoclose
feature is now off and the gate will remain open indefinitely.
The next signal received on Trg will clear the Autoclose Override feature,
close the gate, and set the Autoclose feature back to normal.
4. Autoclose Advanced Options
The conditions under which the gate will automatically close can be set within
the Advanced Autoclose options menu:
2. Collision Count
A counter monitors the number of collisions that the gate experiences before
it reaches the fully closed position. If the value exceeds the value set in the
Multiple Collision Counter the controller shuts down until the next valid
trigger is received. As an indication, the status LED will flash four times every
two seconds. The Multiple Collision fault indication will continue to flash
indefinitely or until a valid trigger has been received.