Buzzer Feedback
The VECTOR2 controller is equipped with an onboard buzzer which is used for various
features and functions on the controller. One of the functions it provides is audible
diagnostic feedback as detailed
Page 74
Inhibitor
name
Break-in Alarm
Ambush Alarm
Auxiliary Overload
Holiday Lockout
Emergency Stop
No Limits set
Mains Failure
Beams
broken (any)
Safety Beams
Failure
Fuse Blown
Motor
Disconnected
Bridge
Damaged
Gate Stalled
Multiple Collision
Battery-low
Number
of beeps
Continuous tone
for 30 seconds
Continuous tone
until IRBs are cleared
5 beeps periodically
for 30 seconds
1 beep periodically
for 30 seconds
1 beep periodically
for 30 seconds
3 short beeps for
5 seconds
2 beeps periodically
for 30 seconds
1 beep periodically
for 30 seconds
5 beeps periodically
for 30 seconds
5 beeps periodically
for 30 seconds
5 beeps periodically
for 30 seconds
5 beeps periodically
for 30 seconds
4 beeps periodically
for 10 seconds
Periodic until condition
is cleared by user
(500/500ms)
3 beeps periodically
for 30 seconds
Priority
1
2
5
6
7
9
10
11
12
14
15
16
17
4
3
Fault
type
Alarm
Alarm
Hardware
User
User
Lost
Power
system fault
User
Hardware
Hardware
Hardware
Hardware
Collision
Collision
Power
system fault
Gate
continues
to operate
N/A
N/A
No
No
No
No
Yes
No
No
No
No
No
No
No
User can
correct
error
N/A
N/A
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Gate will close fully and then shut down for two minutes
DOSS
disconnected
5 beeps periodically
for 30 seconds
13
Hardware
No No
Time-barring
1 beep periodically
for 5 seconds
8
User No
Yes
Yes