S Sens1 Slave Motor (MTR S). Connects to the thin PURPLE wire of the
Slave Motor.
S Sens2 Slave Motor (MTR S). Connects to the thin BLUE or ORANGE wire of the
Slave Motor.
M Sens1 Master Motor (MTR M). Connects to the thin PURPLE wire of the
Master Motor.
M Sens2 Master Motor (MTR M). Connects to the thin BLUE or ORANGE wire of
the Master Motor.
Sens + Operator sensor power connection. A 5V output for connecting to the thin
RED sensor wire on both the MTR M and MTR S operators.
Sens - Operator sensor power connection. A 0V output for connecting to the thin
BLACK or GREY sensor wire on both the MTR M and MTR S operators.
Safe CLS Closing edge safety input. (A normally-closed potential-free input.)
As long as a connection between this input and Com is maintained the
controller will behave normally. When this connection is broken it will
prevent the gate from closing if it is stationary, and will stop and reverse
the gate if it is closing. This input has no effect if the gate is opening.
If the Safe CLS function is not required a link must be fitted
between Safe CLS and Com for the controller to operate
normally.
Safe OPN Opening edge safety input. (A normally-closed potential-free input.)
For as long as a connection between this input and Com is maintained the
controller will behave normally. When this connection is broken it will
prevent the gate from opening if it is stationary, and will stop and reverse
the gate if it is opening. This input has no effect if the gate is closing.
If the Safe Open and reverse functions are not required a link
must be fitted between safe Open and Com for the controller to
operate normally.
26. Description of Terminal Functions
Page 69
LCK/STP Holiday Lockout or gate stop input. (A normally-closed potential-free
input.) For as long as a connection between this input and Com is
maintained the controller will behave normally. But, when this connection
to Com is broken all inputs are inhibited, and if the gate is moving it will
stop.
If the LCK function is not required a link must be fitted between
LCK and Com.
When setting up the controller for the first time or after a full reset back to the Factory Default
has been performed, the system will electronically override the Safety Inputs and allow the
system to function without the links. However if safeties are connected to either or both inputs,
thereafter there must be a normally-closed circuit maintained for the system to operate
correctly. I.e. if Safety Beams are fitted and then removed, the circuit which is affected must be
replaced with a wire link to create a normally-closed circuit.