cable fatigue, or excessive tension on the cable, may cause the actuators to
behave erratically or to stop operating altogether
Page 38
4. Check that the charger and battery are
connected to the controller.
7. Check that the origin has been correctly
set (see page 25).
Setting the Limits
8A. For an outward opening gate, ensure that
the gate is in the fully-open position and
the operator locked.
8B. If the gate opens inward, the limit setup
procedure must be started with the gate in
the fully-closed position. Check that the
operator is locked.
9. If powering up the system ex-factory, it will
request for the Operating Profile (Operating
Standard) to be set. Select from the list the
Profile that will suit the specific region.
With this set, the system will automatically
proceed to the Limit Setup Menu. Follow
the onscreen instructions to complete the
setup procedure.
If powering up with the Profile set but no
limits set, the system will automatically
proceed to the Limit Setup Menu. Follow
the onscreen instructions to complete the
setup procedure.
If powering up at any stage after that, push
and hold the Setup button ( ) for three
seconds.
FIGURE 64
Ensure that the battery polarity
is correct.
5. Switch on the mains supply (via isolator).
6. Ensure that both the controller and charger
are effectively earthed for improved
lightning protection.
Charger
Battery
FIGURE 62
Origin
marker
Open
FIGURE 63