Centurion VECTOR2 Installation Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
Page 30
FIGURE 47
FIGURE 46
1400mm extended
1000mm retracted
For V400 (400mm operator)
120°
100°
110°
90°
80°
70°
60°
Gate opening angle
Gate swing angle
90° or less
100°
110°
120°
B Value
200
180
130
110
A Value
160
120
120
110
(Only for a 2.5 metre gate or shorter)
Recommended positions
110mm for A or B would ensure a 10mm clearance between the operator and
gate if the gate is 50mm thick.
Alternative positions
Gate
swing
angle
60° - 90° or less
100°
110°
120°
A+B
should
not exceed
380mm
310mm
265mm
220mm
A and B must each be greater
Up to 1.5
metres
110mm
110mm
110mm
Up to 2
metres
110mm
110mm
110mm
Up to 2.5
metres
110mm
110mm
110mm
Up to 3
metres
120mm
120mm
Up to 3.5
metres
140mm
140mm
Up to 4
metres
160mm
160mm
Not
recommended
Page view 33