20. Charger and Pillar Light Connections
90V /220V
-240V AC
Mains in
E
N
L
Protection fuse
on mains input
to charger
(rating: 250mA slow blow)
Auxiliary
supply
Pillar
Light
Neutral
Live
N
L
E
Fuse protection
The following protection fuses are provided on the system:
Item
Main controller
Motor Circuit - fuse per channel
Light circuit
Auxiliary supply
Charger
Mains Input
Type
Automotive Fuse (25 x 7)
5 x 20mm
Electronic fuse - not replaceable
5 x 20mm
Rating
15A
3A Fast Blow
3A
250mA Fast Blow
To reset: Power off controller for at least one minute and re-apply power