3. IR Beam Test (only compatible with i5 Safety Beams; not compatible with
wireless Safety Beams).
Automatically tests the Safety Beams before each gate cycle. (E.g. as
required by CE.)
In order for this feature to work, the power supply negative of the beam
transmitter must be wired to the Safe Com terminal of the controller.
4. IRBO=IRBC
Configures the opening beam to act as a closing beam while the gates
are closing. This allows one set of Safety Beams to be used across the
line of the driveway up to where the gates open.
5. IR Beam Alarms
While the gate is fully closed, this feature allows the following alarms:
FIGURE 81
Alarm
Intruder
blocks beam
Adjustable
beam broken
time
A. Ambush Alarm
Activates an alarm if either the
Opening or Closing Beams
have been continuously
interrupted for a pre-defined
time. The alarm will remain
activated while the beams are
interrupted. For example, if a
would-be intruder covers the
Safety Beams so that when the
gate is opened, the gate will
stay open, the system will
detect this beam override
taking place and set off an
alarm.
B. IR Beam Broken Time
The time that the Beams must be interrupted before the alarm is
activated.
Intruder breaks beam
while loitering at gate
Alarm
C. Break-in Alarm
Activates an alarm if the
Closing Beam on the outside of
the property is interrupted. The
alarm remains activated while
the Beams are broken, and for
a period of 30 seconds
thereafter. This time is fixed.
If this alarm is used, it is recommended that TWO parallel Closing
Beams are used to reduce the chance of false triggering.
FIGURE 82