Centurion VECTOR2 Installation Manual Page 64

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 63
Page 60
1. Courtesy Light time
The time that the Courtesy Light will remain activated can be set from four
seconds to ten hours in one second increments.
2. Light profile
The Courtesy Light can be selected to operate according to one of the
following:
A. Courtesy Light as explained earlier
B. Pre-flashing Mode
If Pre-flashing Mode A, B or C is selected, the behaviour of the Courtesy Light
will be as follows:
Mode A will turn on the Courtesy Light only while the gate is moving
Mode B will flash the Courtesy Light during the Pre-opening and
Pre-closing Delays, as well as while the gate is moving
Mode C will turn on the Courtesy Light during the Pre-opening and
Pre-closing Delays, as well as while the gate is moving
In these Pre-flashing Modes, the timed Courtesy Light functionality is not
available
Menu 10 - General Features
1. Operator
This menu item allows the user to set the type of V-Series operator currently
being used with the controller. Always ensure that VECTOR is selected.
When not in Setup Mode, i.e. Normal Mode, the currently-enabled operator
will be displayed in the bottom left-hand corner of the LCD screen, with VC
indicating VECTOR.
2. Operating Standard
Regional Operating Standards can be set. Applying this setting will
automatically configure the controller settings to conform to the specific
region’s standard. (E.g. UL325 or CE.)
3. Reset Options
The controller settings can be reset through the Reset Options menu.
Various reset options are available:
A. Factory Defaults - All settings will be restored to the default values
dictated by the Operating Standard/Profile that is currently selected.
All remote controls and gate limits will not be affected.
B. Delete All Remotes - Delete all the remotes stored in the system; no
settings affected.
C. Reset All - Clears and defaults the system completely. The unit will be
reset to the Factory Default settings in addition to clearing all remotes and
time-periods.
4. Diagnostic Screen
Allows a diagnostic screen to be displayed. This can be useful when
troubleshooting, but requires some technical knowledge.
5. Round Test Button
Allows the round test button on the controller to be disabled, in cases where
higher security is required.
Page view 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 81 82

Comments to this Manuals

No comments